Cembre’s offer also includes civil construction systems
indirect clamping
One way, single pole terminal blocks for conductors sections from 0.5 to 35 sqmm.
Self contained and robust, they are ideal for the fast and safe installation for industrial and domestic applications.
The indirect clamping of the "ZETAmini" terminal blocks guarantees a low and stable contact resistance.
The easy-entry receptacle also grants a fast and reliable insertion of the cable.
Type | Nominal section |
Connecting capacity* No. of conductors x section |
|
---|---|---|---|
Z2.5-1 | 2,5∎ |
2 x 2,5∎ R/F
2÷3 x 1,5∎ R/F
2÷5 x 1,0∎ R/F
|
2÷6 x 0,75∎ R/F
2÷10 x 0,5∎ R/F
2÷18 x Ø0,4÷0,6 mm
communication type wire
|
Z6-1 | 5∎ |
2 x 6∎ R/F
2÷3 x 4∎ R/F
2÷4 x 2,5∎ R/F
2÷6 x 1,5∎ R/F
2÷6 x 1∎ R/F
|
2÷10 x 0,75∎ R/F
2÷12 x 0,5∎ R/F
(1 x 6∎F) + (4 x 1,5∎F)
(1 x 6∎F) + (2 x 2,5∎F)
|
Z10-1 | 10∎ |
2 x 10∎ R/F
2÷3 x 6∎ R/F
2÷5 x 4∎ R/F
2÷8 x 2,5∎ R/F
|
2÷12 x 1,5∎ R/F
2÷20 x 1∎ R/F
2÷25 x 0,75∎ R/F
(1 x 6∎F) + (1 x 4∎F) + (2 x 2,5∎F) + (3 x 1,5∎F)
|
Z16-1 | 16∎ |
2 x 16∎ R/F
2÷3 x 10∎ R/F
2÷5 x 6∎ R/F
|
2÷8 x 4∎ R/F
2÷12 x 2,5∎ R/F
2÷18 x 1,5∎ R/F
|
Z25-1 | 25∎ |
2 x 25∎ R/F
2÷3 x 16∎ R/F
2÷4 x 10∎ R/F
|
2÷8 x 6∎ R/F
2÷11 x 4∎ R/F
4÷16 x 2,5∎ R/F
|
Z35-1 | 35∎ |
2 x 35∎ R/F
2÷3 x 25∎ R/F
2÷4 x 16∎ R/F
2÷7 x 10∎ R/F
|
2÷11 x 6∎ R/F |
CEI 23-21-II Ed.1992 (EN 60998-2-1-1993)+VI 1994
EN 60998-1:1993+A1:2001
EN 60998-2-1:1993
CEI EN 60998-1
EN 60998-1:2004 (IEC 60998-1:2002)
EN 60998-2-1:2004 (IEC 60998-2-1:2002).
EN 60998-1:2004
EN 60998-2-1: 2004
Material (Body) | Extinguishant impact- resistant polycarbonate |
Material (Clamps) | Electroplated galvanized steel |
Material (Screws) | Electroplated galvanized steel |
Material (Connection plate) | electrolytic zinc Steel |
IP protection | 20 |
UL94 class | V0 |
Impulse voltage of the insulation | 450 V |
Max application temperature | 185 °F |
ZETAmini | Cable type: flexible copper, Maximum diameter: 0.02 in. |
ZETAmini | Cable type: flexible copper, Minimum section: 20 AWG, Maximum section: 20 AWG |
ZETAmini | Cable type: copper, Minimum section: 20 AWG, Maximum section: 20 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 18 AWG, Maximum section: 18 AWG |
ZETAmini | Cable type: copper, Minimum section: 18 AWG, Maximum section: 18 AWG |
ZETAmini | Cable type: copper, Minimum section: 17 AWG, Maximum section: 17 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 17 AWG, Maximum section: 17 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 15 AWG, Maximum section: 15 AWG |
ZETAmini | Cable type: copper, Minimum section: 15 AWG, Maximum section: 15 AWG |
ZETAmini | Cable type: copper, Minimum section: 13 AWG, Maximum section: 13 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 13 AWG, Maximum section: 13 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 11 AWG, Maximum section: 11 AWG |
ZETAmini | Cable type: copper, Minimum section: 11 AWG, Maximum section: 11 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 10 AWG, Maximum section: 10 AWG |
ZETAmini | Cable type: copper, Minimum section: 10 AWG, Maximum section: 10 AWG |
ZETAmini | Cable type: copper, Minimum section: 7 AWG, Maximum section: 7 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 7 AWG, Maximum section: 7 AWG |
ZETAmini | Cable type: copper, Minimum section: 5 AWG, Maximum section: 5 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 5 AWG, Maximum section: 5 AWG |
ZETAmini | Cable type: copper, Minimum section: 3 AWG, Maximum section: 3 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 3 AWG, Maximum section: 3 AWG |
ZETAmini | Cable type: copper, Minimum section: 2 AWG, Maximum section: 2 AWG |
ZETAmini | Cable type: flexible copper, Minimum section: 2 AWG, Maximum section: 2 AWG |