Cembre

Points of View Categories Applications Catalogues

TRANSPARENT LEGENDS
CodeMG-TAP-CCS

15mm precut, for legend bases

MG-TAP-CCS transparent legends may be printed or used as protective covers for MG-TAP or TAP legends, PT and PL type legend bases and RT-TAP rail.

Certificates

2011/65/EU 2011/65/EU

Laboratory Test

CEI EN 60950-1

i INDELIBILITY

Information technology equipment - Safety
Part 1: General requirements
§ 1.7.11 Durability

Compliance is checked by inspection and by rubbing the marking by hand for 15 s with a piece of cloth soaked with water and again for 15 s with a piece of cloth soaked with hexane.

After this test, the marking shall be legible; it shall not be possible to remove marking plates easily and they shall show no curling.

CEI EN 61010-1

i INDELIBILITY

Ed.2 equivalent to VDE 0411-1

Safety indications for electric devices for measurement, control and laboratory use
Part 1: General indications

This regulation requires that both material and the print shall withstand‚ cleaning with chemical agents commonly used in industry.

By rubbing manually by hand, without excessive pressure, for 30 seconds with a cloth soaked in the specific detergent or, if not specifi ed, Isopropyl Alcohol.

CEMBRE STANDARD

i INDELIBILITY

This test was created to simulate cleaning with chemical products commonly used on various surfaces.

By wiping with a cloth soaked in 95% Ethanol 30 times and making a visual inspection after every 10 passes.

UNI EN ISO 175

i EFFECT OF IMMERSION INLIQUID CHEMICALS

The standard specifies methods for exposing plastic test samples to liquid chemical agents and for determining changes in characteristics caused by this exposure. It includes the immersion test for 24 hours of the entire surface of the test sample and applies to all solid plastic materials, submitted in the form of printed or extruded materials, plates, pipes, bars or sheets with a thickness greater than 0.1 mm.

The test samples are completely immersed in a test liquid for a specified time and temperature.

Their characteristics are determined before immersion, after removal from the liquid and after drying.

The test methods specified are the following:

  • Changes in mass, dimensions and appearance, immediately after removal from the liquid and after drying
  • Change in the physical characteristics (mechanical, thermal, optical, etc.) immediately after removal from the liquid and after drying
  • The quantity of liquid absorbed

The liquids used by Cembre for this test are: Hydrochloric acid, Nitric acid, Hydrofluoric acid

Technical characteristics Other characteristics

Material Plasticised transparent PVC
UL94 class V0
Min operating temperature range -30 °C
Max operating temperature range 60 °C
Geometric shape rectangular with square corners
Precut yes

Media gallery other media

application 01
application 02

List of products

MG-TAP-CCS

Loading...

notes and legal information

Cembre Via Serenissima, 9 - 25135 Brescia - ITALY
© Copyright 2018 Cembre S.p.A.

CODICE FISCALE – P.IVA: 00541390175
ISCRIZIONE AL REGISTRO DELLE IMPRESE: n. 00541390175 Brescia
CAPITALE SOCIALE: € 8.840.000 i.v.